Search results for "Image guidance"

showing 7 items of 7 documents

Absolute volume of the rectum and AUC from rectal DVH between 25Gy and 50Gy predict acute gastrointestinal toxicity with IG-IMRT in prostate cancer

2016

International audience; Background: To determine whether dose/volume specific endpoints (DVSE) or Area under the rectal DVH curve (rAUC) better predict acute gastrointestinal (GI) toxicity in prostate cancer patients treated with IMRT in the era of daily image guidance (IG-IMRT). Methods: A set of DVSE was recorded from V25 to V75 (increments of 5Gy) (both in % and in cc) for 180 men. The rAUC was calculated for doses ranging between 25Gy and 50Gy (rAUC(25-50)). Univariate and multivariate logistic regressions were performed to determine the relationship between DVSE or rAUC(25-50) and the appearance of any acute GI toxicity. Results: The rates of acute grade 1 (G1), G2 and G3 GI toxicities…

OncologyMale[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/Imagingmedicine.medical_treatmentGastroenterology030218 nuclear medicine & medical imaging[ SDV.CAN ] Life Sciences [q-bio]/Cancer[ SDV.IB.MN ] Life Sciences [q-bio]/Bioengineering/Nuclear medicineProstate cancer0302 clinical medicineProstateLarge intestineConformal Radiation-Therapy[ SDV.IB.IMA ] Life Sciences [q-bio]/Bioengineering/ImagingAged 80 and overGastrointestinal tractProstate cancerRadiotherapy DosageMiddle Aged3. Good healthmedicine.anatomical_structureImpactOncologyRadiology Nuclear Medicine and imaging030220 oncology & carcinogenesisArea Under CurveToxicityImage Guidancemedicine.medical_specialtyRectum[SDV.CAN]Life Sciences [q-bio]/Cancer[SDV.IB.MN]Life Sciences [q-bio]/Bioengineering/Nuclear medicine03 medical and health sciencesInternal medicinemedicineBiochemical ControlHumansRadiology Nuclear Medicine and imagingRadiation InjuriesAgedRadiotherapybusiness.industryResearchRectumProstatic Neoplasmsmedicine.diseaseRadiation therapyAcute rectal toxicity predictive factorLogistic ModelsRadiotherapy Intensity-ModulatedbusinessAbsolute volumeRadiation Oncology (London, England)
researchProduct

Surgery of the Cranio-Vertebral Junction: Image Guidance, Navigation, and Augmented Reality

2019

Due to the density of essential, small, and mobile structures, mastering the surgical anatomy of the craniovertebral junction may be extremely challenging. Quality and safety of interventions can be improved using navigation. Currently, patient-specific anatomy preparation, surgical planning, intervention, and quality assessment are disconnected actions performed in different conditions and environments and by multiple team members. The whole process needs to be integrated by surgeons performing the intervention. The complexity of the process exposes to errors and degraded precision. It is therefore relevant to develop tools that reduce the need to extrapolate and simplify the information i…

Image-guided surgerySurgical anatomyProcess (engineering)Computer scienceHuman–computer interactionmedia_common.quotation_subjectQuality (business)Augmented realityImage guidanceSurgical planningmedia_commonInformation integration
researchProduct

Transcranial magnetic resonance-guided focused ultrasound surgery at 1.5T: a technical note.

2019

Magnetic resonance-guided focused ultrasound is one of the emerging non-invasive technologies offering both image guidance and thermal monitoring. In recent years transcranial application of this technology is starting to impact heavily the neuroscience field. We present here the imaging protocol and the technological methods successfully used with a transcranial magnetic resonance-guided focused ultrasound system certified for clinical treatments of functional neurological disorders, integrated for the first time with a 1.5T magnetic resonance scanner. Compared to the body radiofrequency coil (the one commonly used with transcranial magnetic resonance-guided focused ultrasound system integ…

Maleminimally invasive surgical procedureComputer sciencebraininterventionalSignal-To-Noise RatioNeurosurgical ProcedureMagnetic Resonance Imaging InterventionalFocused ultrasoundNeurosurgical Procedures030218 nuclear medicine & medical imagingMagnetic resonance guided focused ultrasound surgery03 medical and health sciences0302 clinical medicinemedicinemagnetic resonance imagingHumansGeneral NeuroradiologyRadiology Nuclear Medicine and imagingImage guidanceAgedmedicine.diagnostic_testtomography X-ray computedMagnetic resonance scannerinterventional magnetic resonance imagingSettore MED/37 - NeuroradiologiaMagnetic resonance imagingTechnical noteGeneral MedicineSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)minimally invasive surgical proceduresstereotactic techniqueTreatment Outcomebrain; high-intensity focused ultrasound ablation; interventional magnetic resonance imaging; minimally invasive surgical procedures; stereotactic techniques; aged; female; high-intensity focused ultrasound ablation; humans; male; neurosurgical procedures; signal-to-noise ratio; tomography X-ray computed; treatment outcome; magnetic resonance imaging; interventionalElectromagnetic coilstereotactic techniquesHigh-Intensity Focused Ultrasound AblationFemaleNeurology (clinical)Settore MED/36 - Diagnostica Per Immagini E RadioterapiaTomography X-Ray Computed030217 neurology & neurosurgeryHumanRadiofrequency coilBiomedical engineeringThe neuroradiology journal
researchProduct

Prospective Image Quality and Lesion Assessment in the Setting of MR-Guided Radiation Therapy of Prostate Cancer on an MR-Linac at 1.5 T: A Compariso…

2021

The objective of this study is to conduct a qualitative and a quantitative image quality and lesion evaluation in patients undergoing MR-guided radiation therapy (MRgRT) for prostate cancer on a hybrid magnetic resonance imaging and linear accelerator system (MR-Linac or MRL) at 1.5 Tesla. This prospective study was approved by the institutional review board. A total of 13 consecutive patients with biopsy-confirmed prostate cancer and an indication for MRgRT were included. Prior to radiation therapy, each patient underwent an MR-examination on an MRL and on a standard MRI scanner at 3 Tesla (MRI3T). Three readers (two radiologists and a radiation oncologist) conducted an independent qualita…

0301 basic medicineCancer ResearchIntraclass correlationImage qualityPIRADSFleiss' kappalcsh:RC254-282ArticleLesion03 medical and health sciences0302 clinical medicineimage qualityMedicineEffective diffusion coefficientimage guidanceRadiation oncologistMR-Linacmedicine.diagnostic_testbusiness.industryMagnetic resonance imaginglcsh:Neoplasms. Tumors. Oncology. Including cancer and carcinogenslesion detection030104 developmental biologyadaptive radiotherapyOncologyprostate carcinoma030220 oncology & carcinogenesismpMRImedicine.symptombusinessNuclear medicineKappaCancers
researchProduct

Evaluation of robot-guided minimally invasive implantation of 2067 pedicle screws

2017

ObjectiveRecent studies have investigated the role of spinal image guidance for pedicle screw placement. Many authors have observed an elevated placement accuracy and overall improvement of outcome measures. This study assessed a bi-institutional experience following introduction of the Renaissance miniature robot for spinal image guidance in Europe.MethodsThe medical records and radiographs of all patients who underwent robot-guided implantation of spinal instrumentation using the novel system (between October 2011 and March 2015 in Mainz and February 2014 and February 2016 in Regensburg) were reviewed to determine the efficacy and safety of the newly introduced robotic system. Screw posit…

AdultMalemedicine.medical_specialtyPercutaneousRadiographyYoung Adult03 medical and health sciences0302 clinical medicineRobotic Surgical ProceduresPedicle ScrewsHumansMedicineImage guidancePedicle screwAgedAged 80 and over030222 orthopedicsLumbar VertebraeSpinal instrumentationbusiness.industryThe RenaissanceRoboticsGeneral MedicineMiddle AgedSurgeryRadiographySpinal FusionRobotic systemsRobotFemaleSurgeryNeurology (clinical)Tomography X-Ray Computedbusiness030217 neurology & neurosurgeryNeurosurgical Focus
researchProduct

Image guidance to improve reliability and data integrity of transcranial Doppler sonography.

2012

Abstract Background Principles and accuracy of image-guided transcranial Doppler (IG TCD) sonography have been published recently. However, it remains open whether combination of image guidance and TCD offers an additional clinical advantage. This study scores the accuracy of conventional TCD examinations and investigates the potential improvement of TCD data integrity and reliability regarding the additional use of IG. Methods Conventional TCD was performed by a group of experienced investigators, who were blinded to images of a navigation system tracking the Doppler probe, whereas an independent observer documented the TCD findings, acquired by the investigators, due to saving spatial dat…

Intracranial Arteriovenous MalformationsMalemedicine.medical_specialtyNeuronavigationUltrasonography Doppler TranscranialMagnetic resonance angiographyNeurosurgical Procedures03 medical and health sciencessymbols.namesake0302 clinical medicinePostoperative Complications030202 anesthesiologyImage Processing Computer-AssistedMedicineHumansVasospasm IntracranialThrombolytic TherapyImage guidanceAgedmedicine.diagnostic_testbusiness.industryData CollectionTranscranial doppler sonographyUltrasoundReproducibility of ResultsGeneral MedicineMiddle AgedSubarachnoid HemorrhageTranscranial DopplerCerebral Angiographycardiovascular systemsymbolsSurgeryFemaleNeurology (clinical)RadiologybusinessDoppler effect030217 neurology & neurosurgeryMagnetic Resonance AngiographyCerebral angiographyDilatation PathologicClinical neurology and neurosurgery
researchProduct

Image-Guided Transcranial Doppler Ultrasound for Monitoring Posthemorrhagic Vasospasms of Infratentorial Arteries: A Feasibility Study

2019

Background A considerable number of patients with subarachnoid hemorrhage (SAH) develop vasospasms of the infratentorial arteries. Transcranial Doppler sonography (TCD) is used to screen for vasospasm. In this study, we used a technical modification that combines TCD with an image guidance device that the operator can use to navigate to the ultrasonic window and to predefined intracranial vascular targets. Our aim was to analyze the feasibility, spatial precision, and spatial reproducibility of serial image-guided TCD of infratentorial and—for comparison—supratentorial arteries in the clinical setting of monitoring for vasospasm after SAH. Methods The study included 10 SAH patients, who eac…

AdultMaleSubarachnoid hemorrhageComputed Tomography AngiographyUltrasonography Doppler TranscranialCerebral arteriesBrain Ischemia03 medical and health sciencessymbols.namesake0302 clinical medicinemedicineHumansVasospasm Intracranialcardiovascular diseasesImage guidanceVertebral ArteryAgedComputed tomography angiographyReproducibilitymedicine.diagnostic_testbusiness.industryReproducibility of ResultsVasospasmCerebral ArteriesMiddle AgedSubarachnoid Hemorrhagemedicine.diseaseCerebral AngiographyTranscranial DopplerBasilar Artery030220 oncology & carcinogenesiscardiovascular systemsymbolsFeasibility StudiesFemaleSurgeryNeurology (clinical)businessNuclear medicineDoppler effectBlood Flow Velocity030217 neurology & neurosurgeryWorld Neurosurgery
researchProduct